In a serious and responsible attitude, we will provide every product and attentive service for every customer. Pay attention to details, keep improving, and constantly upgrade, so that our equipment accuracy, speed and intelligence continue to improve, the machine operation is simple, convenient and easy to use. Consultation hotline (7 * 24 hours)188-2007-2813
A common fault analysis quantitative filling machine
Problem a, quantitative filling machine for filling quantity is not allowed
In the process of filling, often feed chute, destabilize level; Can fill by increasing feed rate, or to turn down filling material overhead ball valve, reset the filling time (longer stacking time) slow filling speed to solve.
Question 2, if appear digital dial code or after the unit time is not change, then close to plug in the power supply;
Problem 3, liquid level stable, filling quantity is not accurate;
May cause is sundry jam filling channel, mainly in entry or manger in filling material mouth, check and clean can.
Problem four, shut down after the filling mouth dripping
1, stacking nozzle orifice is damaged, reveal a mouth filling material finishing orifice, the diameter of the orifice is not greater than 7.5 mm. Fixed aperture on the water sand paper after grinding flat spot face gently.
1, stacking nozzle orifice is damaged, reveal a mouth filling material finishing orifice, the diameter of the orifice is not greater than 7.5 mm. Fixed aperture on the water sand paper after grinding flat spot face gently.
2, filling head ball valve damage, need to replace the ball valve.
Five, touch switch after not fill material, time relay digital indicator LED flashing:
Note material switch damage or loose time relay base, replace the same note material switch or press tight time relay base.
Question 6, touching note after the switch, time relay digital LED lights flashing, but no filling material:
First check whether the presence of air pressure or too low, such as air pressure required (4-6 kg/cm2), may be electromagnetic valve coil damage or pneumatic valve core was stolen card dead, can pull the power supply, open the plate, with a twisted or press the corresponding button beside a solenoid coil, such as valve can reverse action, it indicates that the damage of solenoid coil, if not the reversing, is the valve core is jammed, can replace solenoid coil or decomposition valve repair (need electrical or pneumatic sense of talent for decomposition or check).